Dehumidifiers, also known as dehumidifiers, dryers and dehumidifiers, can generally be divided into civil dehumidifiers and industrial dehumidifiers, which are part of the air conditioner family. A conventional dehumidifier is generally composed of a compressor, a heat exchanger, a fan, a water reservoir, a casing and a controller. The fan draws moist air into the device and passes through the heat exchanger. At this time, the water molecules in the air condense into water droplets, and the treated dry air is discharged out of the unit to keep the indoor humidity at an appropriate relative humidity.
Main model:
Refrigeration dehumidifier
Refrigeration dehumidifiers can be roughly divided into ordinary type, cooling type and temperature regulating type. Ordinary dehumidifier refers to a dehumidifier in which the air is cooled and dehumidified by the evaporator and heated by the reheater to reduce the relative humidity. The condensation heat of the refrigerant is taken away by the air flowing through the reheater, and its outlet temperature cannot be adjusted. It is only used for heating and dehumidification.
Cooling dehumidifier means that on the basis of ordinary dehumidifiers, most of the condensation heat of the refrigerant is taken away by the water-cooled or air-cooled condenser, and only a small part of the condensation heat is used to heat the air after the evaporator for cooling and dehumidification Dehumidifier.
The temperature regulating dehumidifier is based on the ordinary dehumidifier, which takes away all or part of the condensation heat of the refrigerant through a water-cooled or air-cooled condenser, and the remaining condensation heat is used to heat the air after the evaporator and can adjust the temperature of the outlet air. Dehumidifier.
Pipe dehumidifier
The pipeline dehumidifier uses an evaporator to cool and dehumidify the air, recover the condensation heat of the system, and make up for the heat lost in the air during the cooling and dehumidification process. It is an energy-saving and dehumidifying method. Provides a pipe-type temperature and humidity control method and equipment, which can heat, cool and dehumidify the room at different indoor and outdoor temperatures to meet the requirements of indoor temperature and humidity. The humidity system is mainly composed of cooling dehumidification mode, temperature regulation dehumidification mode, temperature regulation dehumidification mode, temperature regulation dehumidification mode, etc., heating dehumidification mode, heating mode and automatic defrosting mode.
Common sense of dehumidifier
1. In industrial products, optical lenses, magnetic recording materials, image films, electronic information media, electronic original devices, instrumentation, powder materials, paper, wood, silk, leather, tobacco, food, tea, grain, etc. are all needed Items that control humidity.
2. Humidity and temperature in the air are everywhere. In the southern yellow plum season, the temperature is not high and the humidity is high, and people will feel stuffy and uncomfortable.
3. The dehumidifier should not be used near the heat source, and the air inlet and outlet should be kept unblocked. Generally speaking, the dehumidifier should be placed in the middle of the space, and there should be enough space around it. Don't pile things up.
4. During the operation of the dehumidifier, it is normal for hot air to be discharged from the air outlet. In winter, the humidity is low and the temperature of the air outlet drops significantly, which is normal.
5. When purchasing a dehumidifier, the calculation of the dehumidification capacity should take into account indicators such as noise. Generally speaking, dehumidifiers with greater dehumidification capacity are noisier and belong to the type of industrial equipment. If you need less noise and dehumidification to meet the requirements, it is recommended to buy more small dehumidifiers.
6. Measure the nominal dehumidification capacity under standard environmental conditions. If the standard dehumidification capacity is 50L/D, it means the water output measured in an environment of 30°C/RH80% for 24 hours.