Dehumidifiers are very popular in industrial production. The lowest temperature that industrial dehumidifiers can reach in the process of dehumidification is 35%. When using industrial dehumidifiers, the dehumidifier must be used in accordance with the standard method, so that there will be more Good dehumidification effect.
1. Condensate water during operation of industrial dehumidifier
The amount of condensed water is relatively large and is continuously discharged. Plant dehumidifier cooling type dehumidifier means that on the basis of general dehumidifiers, most of the condensation heat of the refrigerant is taken away by the water-cooled or air-cooled condenser, and only a small part of the condensation heat is used to heat the air after the evaporator. Dehumidifier that can be used for cooling and dehumidification. Warehouse dehumidifier humans have a wide tolerance range for air humidity. Generally, only 2 to 3 months of a year belong to the humid period, and most consumers usually endure it. In addition, the dehumidification function of the air conditioner is also easy for consumers to ignore the necessity of the dehumidifier, and only regard it as the icing on the cake. In the case of water leakage, it is necessary to check whether the external drain pipe is aging or cracked; whether the connection between the hose of the condensate pan of the dehumidifier and the drain connection port is not loose; or the V-shaped groove or the V-shaped groove of the water trap Whether the solder joints are fake soldering, etc., so you need to check the symptomatic solution one by one.
2, dressing compressor for the inspection process of thermal insulation cotton
During the operation of the dehumidifier, the refrigerant enters the two units from the compressor through the copper pipe and capillary tube, taking away the moisture in the moist air passing through the evaporator. This is because the dew point of the copper tube of the evaporator is very low, and the condensate generated on the outer wall of the copper tube will leak because the insulation cotton is not properly wrapped.
3. Operation in the dehumidifier
After the dehumidifier runs for a period of time, the consumption of refrigerant will decrease, or the leakage of refrigerant may be caused by defects in the manufacturing process. At this time, it will happen that the evaporator cannot be transferred in time due to lack of refrigerant, resulting in icing on the lower end of the aluminum fin of the evaporator, and the defrosting function of the dehumidifier is reduced, and the condensed water on the aluminum fin on the upper part of the evaporator is flowing down because of the condensation. The presence of ice is like spreading everywhere, and the condensed water cannot be discharged to the hose through the drip pan. The troubleshooting method is to contact the manufacturer or the after-sales maintenance point of the dehumidifier manufacturer to add refrigerant to the compressor, and the fault can be resolved.
Usually when using industrial dehumidifiers, you need to pay attention to some small details, which can effectively prevent some problems of industrial dehumidifiers and make the dehumidifiers longer and more durable.